loading
CANWIN — Engineering the Core of Power. Building What Comes Next.
Medium and low voltage  windings 1
Medium and low voltage  windings 2
Medium and low voltage  windings 3
Medium and low voltage  windings 4
Medium and low voltage  windings 5
Medium and low voltage  windings 1
Medium and low voltage  windings 2
Medium and low voltage  windings 3
Medium and low voltage  windings 4
Medium and low voltage  windings 5

Medium and low voltage windings

The consolidated experience in the production of resin transformers and the remarkable quality acquired has allowed the marketing, in addition to the complete transformer, also of low and medium voltage impregnated or encapsulated coils. The design for creation of the core can be provided by CANWIN or on the customer’s indications. This allows us to guarantee a reduction in transportation, import and construction costs of the transformer on site in distant countries.


5.0
design customization

    oops...!

    no product data.

    Go to homepage

    Transformer coil

    Winding material lnsulated with an epoxy resin -environmentally friendly.

    Windings have high mechanical strength and no partial discharge and are non-flammable.

    The  windings are  manufactured with aluminium or copper conductors.


    FACTORY TEST

    For each transformer are prepared and issued a test report, in accordance with IEC 60076. except for routine tests, we also offer type tests and specialised tests to meet all customer requirements. We make what matters work for our customers in a safe and reliable way.

    Medium and low voltage  windings 6


    1. Routine test 

    Measurement of winding resistance

    Measurement of voltage ratio and check of phase displacement

    Measurement of short-circuit impedance and load loss

    Measurement of no-load loss and current

    Separate-source AC withstand voltage test

    Induced AC withstand voltage test

    Partial discharge measurement



    2. Type test

    Lightning impulse test

    Temperature-rise test



    3. Special test

    Partial discharge measurement

    Measurement of sound level

    Short-circuit test


    What are the two types of transformer winding?

    There are two windings in a double coil winding transformer, each wound on the same iron core and connected by alternating magnetic flux. The voltage with more turns is higher, while the voltage with fewer turns is lower. Thus, it can convert one level of voltage into another level with the same frequency.


    What is the difference between low voltage and medium voltage transformers?

    According to American National Standard Institute(ANSI), high voltage transformers can handle a minimum of 115000 volts to a maximum of 11,00,000 volts; medium voltage transformers have a limited capacity of 2400 to 69000 volts; and low voltage transformers have a minimum voltage of 240 and a maximum voltage of 600.


    Voltage Transformers, also known as Potential Transformers, are devices that reduce the voltage from a higher level to a safe or acceptable level. They are parallelly connected transformers that present negligible load to the supply.


    It is possible to accurately measure secondary connecting connections with voltage transformers because they have an accurate voltage ratio and phase relationship. The switchgear in substations is usually on both the high and low voltage sides of the large power transformers. They are widely used in power plants, industrial plants, and traditional electric utility companies. Three types of voltage transformers exist:


    High voltage transformers

    Medium voltage transformers

    Low voltage transformers


    High Voltage Transformers

    A high voltage, an extra-high voltage, or an ultra-high voltage are associated with the transmission of power from the power plant. High voltage transformer winding must be controlled remotely or placed manually for proper maintenance and testing. They are transmitted to increase efficiency. High voltage transformers can be equipped with high voltage windings, high voltage isolations between windings, or both.


    Medium Voltage Transformers

    Voltage is inversely proportional to amperage, so when voltage increases, amperage decreases. Medium-voltage transformers consume more power than low-voltage transformers.


    Low Voltage Transformers

    Low voltage transformers have a rectifier that helps to convert their output into Radio Frequency Interference and direct current. In this type of transformer, electricity converts by transferring current from one set of electric windings to another.


    In many industries, voltage transformers are necessary to power their machines. Schneider Electric India provides a wide range of technology-driven voltage transformers and MV switchgear that help prevent mishaps and protect electrical circuits. With Schneider Electric India's modern solutions, transform your power management capabilities with innovative medium power transformers. They do not compromise on quality and provide trusted products


    Contact us
    Get in touch with us
    Just leave your email or phone number in the contact form so we can send you a free quote for our wide range of designs!
    Related Products
    Specializing in the research and development of Silicon Steel Sheet Cut to Length Lines, power transformers, Silicon Steel Sheet Slitting Lines, and Transformer Foil Winding Machines, the company operates with a strong emphasis on innovation and precision engineering.
    Contact us
    Contact Sales at Ms. Flora Lu
    Mobile:+86 1370-228-2846
    Tel: (+86) 750-887-3161
    Fax: (+86) 750-887-3199
    E-mail: info@canwinsg.com
    Office add: No.1 Pankeng Road, Gonghe Town, Heshan, Jiangmen, GD, China 529700
    Singapore office add: 10, Bukit Batok Crescent, #04-04, The Spire, Singapore 658079
    Copyright © 2026 CANWIN | Sitemap