Canwin is a professional Power Transformer Company & Electrical Transformer Manufacturer
Language
HOME
PRODUCTS
Electrical Equipment
Cut to length lines
Slitting lines
Foil winding machines
Transformers and Distribution Cabinets
Dry type transformers
Oil transformers
Distribution cabinets
Box-type substation
Transformer coil
Transformer Cores
Electrical Materials
Silicon steel
Epoxy resin
Copper and AL foil
Laser Machines
Laser welding machines
Laser cutting machines
Energy Storage Systems
Containerized Energy Storage System
SERVICE
CASES
NEWS
ABOUT US
CONTACT US
NEWS
HOME
>
NEWS
VR
NEWS
Send your inquiry
*
Name
Format error
*
E-mail
Format error
*
Phone/WhatsApp/Skype
Format error
*
Company Name
Format error
*
Content
Format error
Submit
Calculation methods of various losses and impedance voltages of transformers
The power loss of the transformer is divided into iron loss and copper loss. Iron loss is also called no-load loss, which is its fixed loss. It is actually the loss generated by the iron core (also called iron core loss, and copper loss is also called load loss).
November 24, 2022
A new breakthrough in UHV technology! Successful test of new generation a million volt transformer
A new breakthrough in UHV technology! Successful test of new generation a million volt transformer.On Oct. 28, TBEA (20.730, -0.94, -4.34%) was informed that the new generation of direct outlet 1000kV AC extra-high voltage transformer produced by TBEA recently passed all the tests at one time, and TBEA became the first company in China to pass all the tests of the new generation of megavolt transformer at one time.In order to meet the high reliability of high-altitude equipment, TBEA set up a special research group and passed the product development at one time after many special demonstrations and guidance from the State Grid and industry experts.The product adopts a new direct outlet device for the first time and fixes it on the body, avoiding the risks brought by the process of disassembling and reassembling on site after the test of indirect outlet device; adopts a new coil insulation structure for the first time to further improve the insulation characteristics, short-circuit resistance, temperature rise distribution and workshop production process of the product, especially to meet the requirements of transformer temperature rise in high altitude areas; adopts a new oil tank explosion-proof design concept for the first time, significantly improving the transformer's explosion-proof performance. With the application of these new technologies, the technical performance of the new generation of mega-voltage transformers surpasses that of its predecessors, reducing the total loss by more than 80kW and significantly improving the energy efficiency level of the products.The successful test of the new generation of million volt transformer not only improves the safety and stability of China's AC transformer operation in high altitude areas, but also plays a very important role in the consumption of clean energy and ensuring the stable operation of the power grid.Source: China Science and Technology NetworkCANWIN also the equipment supplier for TBEA ,If you have demand for CRGO cutting machine and slitting line and transformers, welcome to contact us.
November 04, 2022
Working principle and basic knowledge of transformer
1. What are the consequences of different connection groups for parallel operation of transformers?Answer: When transformers of different connection groups are operated in parallel, the secondary circuit will generate voltage difference due to different secondary side voltages of transformers Δ U2, because the total phase difference in transformer connection is a multiple of 30 ° Δ The value of U2 is large. If the phase angle difference of the secondary side of the parallel transformer is 30 °, Δ The U2 value is 51.76% of the rated voltage. If the short-circuit voltage Uk of the transformer is 5.5%, the equalizing current can reach 4.7 times of the rated current, which may burn the transformer.A large phase difference produces a large equalizing current, which is not allowed. Therefore, transformers of different groups cannot operate in parallel.
October 27, 2022
The principle, structure and operation and maintenance of transformer gas protection
Gas protection is the main protection for transformer internal faults. It can act sensitively to transformer inter-turn and inter-layer short circuits, iron core faults, internal bushing faults, internal winding disconnection, insulation deterioration and oil level drop. When a fault occurs inside the oil-immersed transformer, the arc will decompose the insulating material and generate a large amount of gas, which flows from the oil tank to the oil pillow, and its intensity varies with the severity of the fault, reflecting the air flow and oil flow The action protection is called gas protection, also called gas protection. During the operation of the transformer, due to internal faults, sometimes we cannot identify and take measures in time, which is easy to cause some accidents. After the protection of the gas relay, the occurrence of similar incidents can be avoided to a certain extent.
October 05, 2022
Multiple shear-stacking integrated iron core machining centers are being manufactured in small batches
Why was Edison alone and not a team of people who invented the electric light bulb?Why was Tesla the only one who discovered electricity and not a team?Why did Coulomb discover the effects of magnetic fields alone and not a team?Because only a very few people can endure loneliness and devote themselves to research without seeking for them, companies that truly have the ability to invent and create often have nothing to do with the company's business scale and the number of R&D personnel, but only with the obsession of team members and years of years. It's all about perseverance!It's harvest season again, good morning everyone!This is the CANWIN equipment manufacturing site. Multiple shear-stacking integrated iron core machining centers are being manufactured in small batches!To know more, Click https://www.canwindg.comEmail: info@canwinsg.com WhatsApp:+8613702282846 #spacertypehighspeedslittingline #transformercore #cuttolengthline #cuttolength #cuttolengthlinemachine #siliconsteelsheetcutting #cuttolengthlinemachinesupplier #drytypetransformermanufacturers #Distributiontransformer #oilimmersedtransformersupplier #cuttolengthlinemanufacturers #transformercore #SlittingLineManufacturer #canwin #automaticallystackedmachine #spacertypeslittingline #highspeedslittingline
September 26, 2022
Intro to CANWIN Dry Type Transformers Canwin
CAWIN Automatic Equipment Manufacturing Co., Ltd. is a supplier of State Grid, China Southern Power Grid, and a professional manufacturer of high-end electrical equipment in China. The main business is electrical intelligent equipment manufacturing, power equipment production customization, high-end intelligent transformer production line series equipment, various dry-type transformers with high performance requirements, and electrical materials trade. The dry-type transformers produced by CANWIN have reasonable design and simple structure. It has the advantages of simple operation, high safety, high sensitivity, low loss, low noise, energy saving and environmental protection. Best-selling at home and abroad, well received.
September 22, 2022
Transformer Core Intelligent Manufacturing Industry Chain Service New Model
At present, all countries in the world generally adopt the transformer core shearing distribution mode, which is also a relatively advanced industrial chain service mode that my country has been paying attention to and learning from. In recent years, with the development of my country's intelligent manufacturing technology, the progress of transformer core intelligent manufacturing technology and the outbreak of new coronary pneumonia have further promoted this progress.
September 16, 2022
Do you know what are the common faults of transformers?
1. Winding failureThere are mainly inter-turn short circuit, winding grounding, phase-to-phase short circuit, wire breakage and joint welding. The reasons for these failures are as follows:① During manufacture or maintenance, local insulation is damaged, leaving defects;② Due to poor heat dissipation or long-term overload during operation, sundries fall into the windings, causing the temperature to be too high and the insulation to age;③ The manufacturing process is poor, the pressing is not tight, the mechanical strength cannot withstand short-circuit impact, and the winding is deformed and the insulation is damaged.
September 15, 2022
Discussion on short-circuit current breaking capacity of low-voltage side circuit breakers of distribution transformers
The short-circuit current breaking capacity of the low-voltage side circuit breaker of the distribution transformer is too small; the influence of the thermal stability current of the cable is not verified in the low-voltage distribution system, which leads to the small cross-sectional area of some distribution circuit cables in the low-voltage distribution system.
September 13, 2022
About transformers, you have to master the knowledge points!
1. What is a transformer?In the AC circuit, the device that increases or decreases the voltage is called a transformer. The transformer can convert any value of voltage into the voltage value we need with the same frequency to meet the requirements of electric energy transmission, distribution and use.For example, the electricity from a power plant has a low voltage level, and the voltage must be increased before it can be transported to a distant power consumption area. The power consumption area must be reduced to a suitable voltage level to supply power equipment and daily electricity. Equipment.
August 25, 2022
Transformers Classic 50 Questions
1. What are the main components of oil-immersed transformers?Answer: The main components of the transformer are: iron core, winding, fuel tank, oil pillow, respirator, explosion-proof pipe, radiator, insulating sleeve, tap changer, gas relay, thermometer, net oil, etc.
August 18, 2022
Measures to improve the short-circuit resistance of power transformers
The power transformer is the hub of transmission and distribution of electric energy, and the core component of the power grid. Its reliable operation is not only related to the power quality of the majority of users, but also to the safety of the entire system. The reliability of a power transformer is determined by its health status, not only depends on the design and manufacture, structural materials, but also closely related to the overhaul and maintenance. The problem of improving the short-circuit resistance of transformers in power systems is discussed.
July 19, 2022
No more~~
1
...
6
7
8
...
10
Copyright © 2026 CANWIN ELECTRIC PTE LTD - www.canwindg.com All Rights Reserved.
Design
Chat
Now
linkedin
whatsapp
whatsapp
facebook
twitter
share
Share
Send Inquiry
Chat Now
Send your inquiry
Name
E-mail
Format error
Phone/WhatsApp/Skype
Company Name
Content
SEND INQUIRY NOW
Choose a different language
╳
English
Tiếng Việt
Türkçe
ภาษาไทย
русский
Português
한국어
日本語
italiano
français
Español
Deutsch
العربية
Српски
Af Soomaali
Sundanese
Українська
Xhosa
Pilipino
Zulu
O'zbek
Shqip
Slovenščina
Română
lietuvių
Polski
Current language:English
SEARCH
Send Your Inquiry
*
Name
*
Phone
*
E-mail
*
Content
Please enter the calculation result.
Please enter the calculation result.
Verification failed. Please re-enter.